Just an electrical correction.
Combined voltage in 3 phased circuit for 230V phase voltage is 400V. For old 220V circuits it's 380V. 360V never existed.
Current in 3 phase circuit can't be just added together when using combined voltage.
However, with resistive AND balanced load (implying perfect 3 phase kettle), you can just calculate single phase current and divide by 3. So the current for 67.2kW in 3 phase circuit would be ~97A per phase.