popeyegui t1_iztwxib wrote

I did this about 5 years ago. Tiled an entire commercial bathroom and realized when I was done that I used pre-mixed drywall compound instead of mastic for the top half. Made an agreement with the owner to replace if the tiles moved or fell within ten years. Nothing has moved yet.

I should note that there’s no shower, so moisture probably isn’t a big factor.